Clogging test
DTI offers an accredited clogging test according to standards EN1253-7:2022 and EN1253-8:2022
The Clogging test 4.5.2 is intended for trapped floor gullies with:
- Mechanical closure
and
- Combined mechanical closure and water seal
The test consists of subjecting the floor gully to several cycles to establish its behavior over time.
A liquid composition of synthetic bathroom greywater is blended. A mix of artificial hair short and long fibres are added to the greywater on the test bench and circulated through the floor gully at a specifiet temperature and flow for a defined number of cycles. By the end of the test, resistance to pressure and odour-tightness test is carried out.
Requirements according the standard:
The floor gullies and their components shall show no visible deformation or damage which could affect their fitness for use/which impair their function (odour tightness and resistance to pressure).
After the test, the functional characteristics shall be maintained. The floor gully shall comply with 4.4.1 and 4.9.1.1.
See how the clogging test is carried out: