Accredited Heat Pump Testing for Certification and European Market Access - Explore Our Climate Chambers
Climate chambers for specialist heat pump testing
Danish Technological Institute offers specialist testing of heat pumps and related products in controlled climate chamber environments. With experienced test specialists and well-established procedures, we help customers document product performance, support compliance work, and gain a reliable basis for product development, certification, and market access.
Our climate chambers are designed to support precise and standardised testing across a wide range of operating conditions. We assess key parameters such as energy efficiency, heating and cooling performance, energy consumption, sound power level, and domestic hot water production. Testing can be carried out in accordance with relevant international standards, EU regulations, recognised European test schemes, or customer-specific requirements.
Our facilities support testing of several product categories, including air-to-water heat pumps, brine-to-water heat pumps, exhaust air heat pumps, air-to-air heat pumps, multifunctional ventilation units, domestic hot water heat pumps, heat pump water heaters, chillers, air conditioners, condensing units, monobloc units, and split systems.
Explore the overview below to learn more about our climate chambers and sound chambers and their specific capabilities.
Related knowledge and next steps
Whether you are looking for accredited testing, support with European market requirements, sound testing, or access to climate chamber facilities, the following resources can help you find the right information for your product and testing needs.
See how a typical test programme is structured - from initial consultation and test setup to real-time monitoring, analysis, and reporting.
Climate Chambers
Climate Chamber B14.1
Testing of Heat Pumps (All Types)
Products: Air-to-water heat pumps, monobloc heat pumps, split heat pumps, etc.
Including flammable refrigerants
Tests: Accredited test, non-accredited test, certification test, development test.
Testing af SCOP/COP, SEER/EER, and DHW testing
Test Method:
Double balance caloriemeter method
Room: L x W x H (mm)
3800 x 2900 x 2300
Door: W x H (mm)
830 x 1800
Maximum Capacity: 9 kW
Room Temperature Range: -40 °C to 50 °C
Humidity Range: 20% to 100% relative humidity
Power: 16 Apm
Standards: EN14511 (part 1 to 4)
EN14825
EN16147 + A1
EN13141-7
EN12897 +A1
EN12897 +A1
Climate chamber is available for rental
Climate Chamber B14.2
Testing of Heat Pumps (All Types)
Products: Air-to-water heat pumps, monobloc heat pumps, split heat pumps, etc.
Including flammable refrigerants
Tests: Accredited test, non-accredited test, certification test, development test.
Testing af SCOP/COP, SEER/EER, and DHW testing
Test Method:
Double balance caloriemeter method
Room: L x W x H (mm)
3800 x 2900 x 2300
Door: W x H (mm)
830 x 1800
Maximum Capacity: 9 kW
Room Temperature Range: -40 °C to 50 °C
Humidity Range: 20% to 100% relative humidity
Power: 16 Apm
Standards: EN14511 (part 1 to 4)
EN14825
EN16147 + A1
EN13141-7
EN12897 +A1
EN12897 +A1
Climate chamber is available for rental
Climate Chamber B14.1-2
Testing of Heat Pumps (All Types)
Products: Air-to-air heat pumps, split heat pumps, exhaust air heat pumps, multifunctional heat pumps, etc.
Including flammable refrigerants
Tests: Accredited test, non-accredited test, certification test, development test.
Testing af SCOP/COP, SEER/EER, and DHW testing
Test Method:
Double balance caloriemeter method
Room: L x W x H (mm)
3800 x 2900 x 2300
Door: W x H (mm)
830 x 1800
Maximum Capacity: 12 kW
Room Temperature Range: -25 °C to 50 °C
Humidity Range: 20% to 100% relative humidity
Power: 16 Apm
Standards: EN14511 (part 1 to 4)
EN14825
EN16147 + A1
EN13141-7
EN12897 +A1
EN12897 +A1
Climate chamber is available for rental
Climate Chamber B14.3
Testing of Heat Pumps (All Types)
Products:Air-to-water heat pumps, monobloc heat pumps, split heat pumps, etc.
Including flammable refrigerants
Tests: Accredited test, non-accredited test, certification test, development test.
Testing af SCOP/COP, SEER/EER, and DHW testing
Test Method:
Double balance caloriemeter method
Room: L x W x H (mm)
5100 x 4800 x 2900
Door: W x H (mm)
1380 x 2240
Maximum Capacity: 30 kW
Room Temperature Range: -25 °C to 50 °C
Humidity Range: 20% to 100% relative humidity
Power: 63 Apm
Standards: EN14511 (part 1 to 4)
EN14825
EN16147 + A1
EN13141-7
EN12897 +A1
EN12897 +A1
Climate chamber is available for rental
Climate Chamber XLTesting of Heat Pumps (All Types)
Products:Air-to-water heat pumps, monobloc heat pumps, split heat pumps, condensing units, etc.
Including flammable refrigerants
Tests: Accredited test, non-accredited test, certification test, development test.
Testing af SCOP/COP, SEER/EER, and DHW testing
Test Method:
Double balance caloriemeter method
Room: L x W x H (mm)
5100 x 4800 x 2900
Door: W x H (mm)
1380 x 2240
Maximum Capacity: 130 kW
Room Temperature Range: -35 °C to 50 °C
Humidity Range: 20% to 100% relative humidity
Power: 125 Apm
Standards: EN14511 (part 1 to 4)
EN14825
EN16147 + A1
EN13141-7
EN12897 +A1
EN12897 +A1
Climate chamber is available for rental
Climate Chamber B14.5Testing of Heat Pumps (All Types)
Products:Air-to-water heat pumps, monobloc heat pumps, split heat pumps, etc.
Including flammable refrigerants
Tests: Accredited test, non-accredited test, certification test, development test.
Testing af SCOP/COP, SEER/EER, and DHW testing
Test Method:
Double balance caloriemeter method
Room: L x W x H (mm)
3690 x 3690 x 2780
Door: W x H (mm)
990 x 1990
Maximum Capacity: 30 kW
Room Temperature Range: -40 °C to 50 °C
Humidity Range: 20% to 100% relative humidity
Power: 63 Apm
Standards: EN14511 (part 1 to 4)
EN14825
EN16147 + A1
EN12897 +A1
EN12897 +A1
Climate chamber is available for rental
Climate Chamber B16.1Testing of Heat Pumps (All Types)
Products:Air-to-water heat pumps, monobloc heat pumps, split heat pumps, exhaust air heat pumps, multifunctional heat pumps, etc.
Including flammable refrigerants
Tests: Accredited test, non-accredited test, certification test, development test.
Testing af SCOP/COP, SEER/EER, and DHW testing
Test Method:
Double balance caloriemeter method
Room: L x W x H (mm)
5250 x 6750 x 3000
Door: W x H (mm)
1500 x 2490
Maximum Capacity: 30 kW
Room Temperature Range: -40 °C to 50 °C
Humidity Range: 20% to 100% relative humidity
Power: 63 Apm
Standards: EN14511 (part 1 to 4)
EN14825
EN16147 + A1
EN13141-7
EN12897 +A1
EN12897 +A1
Climate chamber is available for rental
Climate Chamber B16.2Testing of Heat Pumps (All Types)
Products:Air-to-water heat pumps, monobloc heat pumps, split heat pumps, exhaust air heat pumps, multifunctional heat pumps, etc.
Including flammable refrigerants
Tests: Accredited test, non-accredited test, certification test, development test.
Testing af SCOP/COP, SEER/EER, and DHW testing
Test Method:
Double balance caloriemeter method
Room: L x W x H (mm)
5250 x 6750 x 3000
Door: W x H (mm)
1500 x 2490
Maximum Capacity: 30 kW
Room Temperature Range: -40 °C to 50 °C
Humidity Range: 20% to 100% relative humidity
Power: 63 Apm
Standards: EN14511 (part 1 to 4)
EN14825
EN16147 + A1
EN13141-7
EN12897 +A1
EN12897 +A1
Climate chamber is available for rental
Climate Chamber B16.1 SoundTesting of Heat Pumps, Chillers & Other Products
Products:Heat pumps for heating/cooling, chillers, air conditioners, heat pump water heaters, etc.
Tests: Testing of sound power level, compliance test, vibration test
Room: L x W x H (mm)
5250 x 6750 x 3000
Door: W x H (mm)
1500 x 2490
Maximum Capacity: 20 kW
Room Temperature Range: -25 °C to 50 °C
Humidity Range: 20% to 100% relative humidity
Power: 63 Apm
Standards: EN12102-1
EN12102-2
EN5136
Climate Chamber B16.2 SoundTesting of Heat Pumps, Chillers & Other Products
Products:Heat pumps for heating/cooling, chillers, air conditioners, heat pump water heaters, etc.
Tests: Testing of sound power level, compliance test, vibration test
Room: L x W x H (mm)
5250 x 6750 x 3000
Door: W x H (mm)
1500 x 2490
Maximum Capacity: 20 kW
Room Temperature Range: -25 °C to 50 °C
Humidity Range: 20% to 100% relative humidity
Power: 63 Apm
Standards: EN12102-1
EN12102-2
EN5136
Ask About Climate Chamber Rental
Most of our climate chambers and laboratory facilities are available for rental, giving you access to controlled test environments for product development and testing.
Reach out to Preben Eskerod, Business Manager, for more information about climate chamber rental.
Why Choose our Climate Chambers?
|
|
Reliable Results Through Accredited TestingOur Heat Pump Test Laboratory is accredited according to EN/ISO 17025:2017 by DANAK, supporting consistent testing quality, reliable results, and a strong basis for documentation and compliance. |
|
|
|
Expertise and ComplianceOur test facilities are well established within the European testing landscape. With more than 30 years of experience and over XXXX products tested, we support customers with reliable testing in accordance with current EU legislation and harmonised standards. |
|
|
|
Climate Chambers and DocumentationOur climate chambers are designed to support precise testing under controlled conditions, providing reliable results that help document product performance and support certification, compliance with relevant standards, and market access across European markets. |
|
|
|
Close Collaboration and Live DataWe work in close dialogue with our customers throughout the testing process and provide access to live data, allowing you to follow the progress of your test in real time. This gives you transparency, control, and a clear basis for ongoing decisions. |